Acta Mechanica Slovaca 2018, 22(1):54-61 | DOI: 10.21496/ams.2018.009
Introduction of the Biokinemetric Triangle - a New Surrogate Parameter for Analysis of Spinal Range of Motion
- 1 Department of Neurosurgery, Carl Gustav Carus University Hospital, Technical University of Dresden, 01307 Dresden, Germany
- 2 Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- 3 Department of Biomedical Engineering and Measurement, Technical University of Košice, Letná 9, 042 00 Košice, Slovakia
- 4 Uniklinik Koln, Institute of Neurophysiology, Germany
- 5 Department of Neurosurgery, Auenbruggerplatz 29, 8036 Graz, Austria
- 6 Institute of Neurophysiology, Medical Faculty, University of Cologne, 50937 Cologne, Germany
Background: In preparation for a cervical device study (CDS) we developed a software-based surrogate model in order to analyze pre- and postoperative segmental range-of-motion (ROM) and help determine the optimal height of cervical implants. Besides eliminating surgeon's bias during intraoperative device-height choice, this software-based approach to spinal implantation surgery aims to reduce postoperative neck pain. In this study we evaluated the feasibility of using this surrogate model to determine changes in pre- and postoperative segmental motion characteristics independent of surgeon-related bias of device-height choice.
Methods: The software's surrogate model is based on videofluoroscopic movement recordings in addition to conventional radiographs recorded during standardized movements. Software-based evaluation of segment-specific range-of-motion (ROM) characteristics was based on the newly introduced surrogate parameter "biokinemetric triangle". Depending on changes of the triangles surface area during pre- and post-operative analysis, segment-specific ROM were determined and evaluated with regards to surgery-related ROM changes. Structural pattern recognition was employed to examine whether biokinemetric triangle based ROM analysis is able to discriminate between different implants.
Results: The surrogate parameter biokinemetric triangle software plug-in allows detection of implant-specific functional alterations of segmental movement characteristics (p<0.05). It is a valuable follow-up parameter for the investigation of changes in the segmental motion characteristics after device implantation.
Conclusions: Biokinemetric triangle analysis displays segmental motion characteristics and detects segmental changes after device implantation in CDS. Common range of motion (ROM) analysis based on angular observations requires complete movement execution in order to make significant comparisons, whereas the triangle-based analysis allows movement characterization independent of complete execution.
Keywords: cervical discectomy, cervical prosthesis, cervical cage, biokinemetric triangle, segmental range of motion
Published: March 15, 2018 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- Anderst WJ, Aucie Y. Three-dimensional intervertebral range of motion in the cervical spine: Does the method of calculation matter? Med Eng Phys 2017 41:109-15.
Go to original source...
- Anderst WJ, Donaldson 3rd. WF, Lee JY, Kang JD. Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading. J Biomech. 2015 48(7) 1286-93.
Go to original source...
- Berthonnaud E, Labelle H, Roussouly P, Grimard G, Vaz G, Dimnet J. A variability study of computerized sagittal spinopelvic radiologic measurements of trunk balance. J Spinal Disord Tech 2005 18(1):66-71.
Go to original source...
- Berthonnaud E, Dimnet J, Roussouly P, Labelle H. Analysis of the sagittal balance of the spine and pelvis using shape and orientation parameters. J Spinal Disord Tech 2005 18(1):40-7.
Go to original source...
- Bossert M. Einführung in die Nachrichtentechnik. 2012 Oldenbourg Wissenschaftsverlag.
- Boulay C, Tardieu C, Hecquet J, Benaim C, Mouilleseaux B, Marty C, Prat-Pradal D, Legaye J, Duval-Beaupère G, Pélissier J. Sagittal alignment of spine and pelvis regulated by pelvic incidence: standard values and prediction of lordosis. Eur Spine J 2006 15(4):415-22.
Go to original source...
- Daniels Ah, Paller DJ, Koruprolu S, Palumbo MA, Crisco JJ. Dynamic biomechanical examination of the lumbar spinewith implanted total spinal segment replacement (TSSR) utilizing a pendulum testing system. PLoS One 2013 8(2).
Go to original source...
- Diebo BG, Ferrero E, Lafage R, Challier V, Liabaud B, Liu S, Vital JM, Errico TJ, Schwab FJ, Lafage V. Recruitment of compensatory mechanisms in sagittal spinal malalignment is age and regional deformity dependent: a full-standing axis analysis of key radiographical parameters. Spine 2015 40(9):642-9.
Go to original source...
- Ferrero E, Liabaud B, Challier V, Lafage R, Diebo BG, Vira S, Liu S, Vital JM, Ilharreborde B, Protopsaltis TS, Errico TJ, Schwab FJ, Lafage V. Role of pelvic translation and lower-extremity compensation to maintain gravity line position in spinal deformity. J Neurosurg Spine 2016 24(3):436-46.
Go to original source...
- Gertzbein SD, Seligman J, Holtby R, Chan KH, Kapasouri A, Tile M, Cruickshank B. Centrode patterns and segmental instability in degenerative disc disease. Spine 1985 10(3):257-61.
Go to original source...
- Gertzbein SD, Chan KH, Tile M, Seligman J, Kapasouri A. Moiré patterns: an accurate technique for determination of the locus of the centres of rotation. J Biomech. 1985 18(7):501-9.
Go to original source...
- Gertzbein SD, Holtby R, Tile M, Kapasouri A, Chan KW, Cruickshank B. Determination of a locus of instantaneous centers of rotation of the lumbar disc by moiré fringes. A new technique.
- Guigui P, Levassor N, Rillardon L, Wodecki P, Cardinne L. Physiological value of pelvic and spinal parameters of sagittal balance: analysis of 250 healthy volunteers. Rev Chir Orthop Reparatrice Appar Mot 2003 89(6):496-506.
- Gutman G, Labelle H, Barchi S, Roussouly P, Berthonnaud É, Mac-Thiong JM. Normal sagittal parameters of global spinal balance in children and adolescents: a prospective study of 646 asymptomatic subjects. Eur Spine J 2016 25(11):3650-7.
Go to original source...
- Kwon B, Kim D, Marvin A, Jenis LG. Outcomes following anterior cervical discectomy and fusion: The role of interbody disc height, angulation and spinous process distance. J Spinal Disord Tech 2005 18:304-308.
Go to original source...
- Lafage R, Ferrero E, Henry JK, Challier V, Diebo B, Liabaud B, Lafage V, Schwab F. Validation of a new computer-assisted tool to measure spino-pelvic parameters. Spine J 2015 15(12):2493-502.
Go to original source...
- Legaye J, Duval-Beaupère G. Sagittal plane alignment of the spine and gravity: a radiological and clinical evaluation. Acta Orthop Belg 2005 71(2):213-20.
- Niederer D, Vogt L, Wilke J, Banzer W. On the relevance of surrogate parameter deduction in biomedical research: mediated regression analysis for variance explantation of cervical range of motion. Eur Spine J 2017 26(1):162-166.
Go to original source...
- Okawa A, Shinomiya K, Komori H, Muneta T, Arai Y, Nakai O. Dynamic motion study of the whole lumbar spine by videofluoroscopy. Spine 1998 23(16):1743-49.
Go to original source...
- Pearcy MJ, Bogduk N. Instantaneous axes of rotation of the lumbar intervertebral joints. Spine 1988 13(9):1033-41.
Go to original source...
- Pearcy MJ, Whittle MW. Movements of the lumbar spine measured by three-dimensional x-ray analysis. J Biomed Eng 1982 4(2):107-12.
Go to original source...
- Qi Y, Lewis G. Influence of assigned material combination in a simulated total cervical disc replacement design on kinematics of a model of the full cervical spine: A finite element analysis study. Biomed Mater Eng 2016 27(6):633-46.
Go to original source...
- Rieger B. Deutsches Patent und Markenamt DE102017213625A1.
- Rieger B. Clinical trial registration no.: PNS Study NCT02936765/ PNR Study NCT02936739.
- Rieger B, Jiang H, Reinshagen C, Molcanyi M, Zivcak J, Grönemeyer D, Bosche B, Schackert G, Ruess D. Effects of preoperative simulation on minimally invasive Hybrid Lumbar Interbody Fusion (MIS-HLIF). World Neurosurg. 2017; pii: S1878-8750(17)31092-6.
Go to original source...
- Rieger B, Jiang H, Polanski W, Molcanyi M, Zivcak J, Reinshagen C, Brautferger U, Mysliwiec P, Schackert G, Welsch N. Is an effective functional replacement of a lumbar segment possible? Biokinemetrie as a surgical projection. MOJ Orthop Rheumatol. 2017; 8(4).
Go to original source...
- Rieger B, Reinshagen C, Schackert G, Ruess D, Molcanyi M. Biokinemetrie - prospective surgical solutions in degenerative spine. In review since August 2017: Medical Engineering & Physics.
- Rillardon L, Levassor N, Guigui P, Wodecki P, Cardinne L, Templier A, Skalli W. Validation of a tool to measure pelvic and spinal parameters of sagittal balance. Rev Chir Orthop Reparatrice Appar Mot 2003 89(3):218-27.
- Rousseau MA, Bradford DS, Bertagnoli R, Hu SS, Lotz JC. Disc arthroplasty design influences intervertebral kinematics and facet forces. Spine J 2006 6(3):258-66.
Go to original source...
- Schmidt H, Heuer F, Claes L, Wilke HJ. The relation between the instantaneous center of rotation and facet joint forces - A finite element analysis. Clin Biomech 2008 23(3):270-8.
Go to original source...
- Schwab F, Lafage V, Boyce R, Skalli W, Farcy JP.Gravity line analysis in adult volunteers: age-related correlation with spinal parameters, pelvic parameters, and foot position. Spine 2006 31(25):E959-67.
Go to original source...
- Seligman JV, Gertzbein SD, Tile M, Kapasouri A. Computer analysis of spinal segment motion in degenerative disc disease with and without axial loading. Spine 1984 9(6):566-73.
Go to original source...
- Svedmark P, Berg S, Noz ME, Maguire GQ, Zeleznik MP, Weidenhielm L, Memeth G, Olivecrona H. A new CT method for assessing 3D movements in lumbar facet joints and vertebrae in patients before and after TDR. Biomed Res Int
- Yeager MS, Cook DJ, Cheng BC. Reliability of computer-assisted lumbar intervertebral measurements using a noval vertebral motion analysis system. Spine J 2014 14(2):274-81.
Go to original source...
This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.