Acta Mechanica Slovaca 2013, 17(4):40-47 | DOI: 10.21496/ams.2013.044

Computed Tomography - its Development, Principle and Image Artifacts

Teodor Tóth*, Radovan Hudák
Technical university of Koąice, Faculty of Mechanical Engineering, Department of Biomedical Engineering and measurement, Koąice

Paper deals with medical and industrial tomography and describes they development, utilization and their basic functions and design principles. During sensing of object (patient) may occur artifacts caused by scanning object (body movement, implants, beam hardening). The paper describe the most frequently artifacts and compare the parameters of medical and industrial CT machines.

Keywords: Computed tomography, measurement, artifacts, metrology

Published: October 31, 2013  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Tóth, T., & Hudák, R. (2013). Computed Tomography - its Development, Principle and Image Artifacts. Acta Mechanica Slovaca17(4), 40-47. doi: 10.21496/ams.2013.044
Download citation

References

  1. ®ivčák, J., Hudák, R., Bednarčíková, L., Tóth, T., Trebuňová, M.: Biomechanizmy, implantáty na mieru, ISBN: 978-80-553-1396-2, s. 159, 2012
  2. Shampo, M. A., Kyle, R. A. Godfrey Hounsfield-developer of computed tomographic scanning. Mayo Clinic Proceeding, 71(10), p. 990, 1996 Go to original source...
  3. Seynaeve, P. C., BROOS, J. I.: The history oftomography. Journal Belgede Radiologie. 78(5), p. 284-288, 1995 Go to original source...
  4. Kalender, W. A.: Computed Tomography Fundamentals, System Technology, Image Quality, Applications. Munich: Publicis MCD, 220 p. ISBN 3-89578-081-2, 2000
  5. Reiser, M. F. et al.: Multislice CT. 3rd Ed. Berlin: Springer, 2009, 611 p. ISBN 978-3-540-33124-7. s. 5-10, 2009 Go to original source...
  6. Fuchs, T., Kachelriess, M., Kalender, W. A.: Technical advances in multislicespiral CT. European Journal Of Radiology, 2000, 36 (2), s. 69-73, 2000 Go to original source...
  7. Flohr, T. et al.: First performance evaluation of a dualsource CT (DSCT) system. European Radiology, 16 (2), p. 256-268, 2006 Go to original source...
  8. Jhaveri, K., S. et al.: Effect of multislice CT technology on scanner productivity. American Journal of Roentgenology, 177(4),p. 769-772, 2001 Go to original source...
  9. Endo, M et al.: Effect of scattered radiation on imagenoise in conebeam CT. Medical Physics, 28 (4), p. 469-474, 2001 Go to original source...
  10. Gupta, R. et al.: Ultra highre solution flat-panel volume CT: fundamental principles, design architecture, and system characterization. European Radiology. 16(6), s.1191-1205, 2005 Go to original source...
  11. Barrett, J. F., Keat, N.: Artifacts in CT: Recognition and Avoidance. Radio Graphics, 24 (6), p.1679-1691, 2004 Go to original source...
  12. Barrett, J. F. et al.: Cardiac CT scanning. In MHRA Report 03076. [online]. London, England: Medicines and Healthcare Products Regulatory Agency, 2003. 36 p. [cit.2010.06.06] Dostupné na internete: http://www.cep.dh.gov.uk/. ISBN 1 84182 746 0, 2003
  13. Seeram, E.:Computed tomography: physical principles, clinical applications and quality control. 2nd ed. Philadelphia, Pa: Saunders, ISBN 9780721681733. p. 174-199, 2001
  14. Trebuňová, M, Dankovčík, R., Repovský A. a kol.: Artefakty pri zobrazovaní ultrazvukom, Folia Medica Cassoviensia, in press
  15. ®ivčák, J, Trebuňová, M, Repovský, A, Laputková, G.: Artefakty spôsobené pacientom pri zobrazovaní magnetickou rezonanciou. Lékař a technika - Clinician and technology, ISSN 0301-5491, 2(43), s. 17-22, 2013
  16. ®ivčák, J, Trebuňová, M, Repovský, A, Laputková, G.: Magnetic resonance image artifact due to the examination method and scanning sequences. Acta Mechanica Slovaca, ISSN 1335 - 2393, 17 (3), s.88-92, 2013 Go to original source...
  17. Hudák, R., ®ivčák, J., Magin R.L.: Applications of Metrotomography in Biomedical Engineering In: Biomedical Engineering - Technical Applications in Medicine. - Rijeka : InTech, 2012 P. 225-244. - ISBN 978-953-51-0733-0 Go to original source...
  18. Kruth, J.P., Bartscherb, M., Carmignatoc, S., Schmittd, R., De Chiffree, L., Weckenmannf, A.: Computed tomography for dimensional metrology, CIRP Annals - Manufacturing Technology, Volume 60, Issue 2, 2011, Pages 821-842 Go to original source...
  19. Weiß, D., Shi Q., Kuhn Ch.: Measuring the 3D resolution of a micro-focus X-ray CT setup, http://www.ndt.net/article/ctc2012/papers/365.pdf
  20. Fedorko, G., Molnár, V., Marasová, D., Grinčová, A., Dovica, M., ®ivčák, J., Tóth, T., Husáková, N.: Failure analysis of belt conveyor damage caused by the falling material. Part 2: Application of computer metrotomography, In: Engineering failure analysis. Vol. 34 (2013), p. 431-442. - ISSN 1350-6307 Go to original source...
  21. Fedorko, G., Molnár, V., Marasová, D., Grinčová, A., Dovica, M., ®ivčák, J., Tóth, T., Husáková, N.: Failure analysis of belt conveyor damage caused by the falling material. Part 1: Experimental measurements and regression models, In: Engineering failure analysis. Vol. 36 (2014), p. 30-38. - ISSN 1350-6307 Go to original source...
  22. http://www.healthcare.siemens.com/
  23. www.gehealthcare.com/

This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.