Acta Mechanica Slovaca 2013, 17(4):40-47 | DOI: 10.21496/ams.2013.044
Computed Tomography - its Development, Principle and Image Artifacts
- Technical university of Koąice, Faculty of Mechanical Engineering, Department of Biomedical Engineering and measurement, Koąice
Paper deals with medical and industrial tomography and describes they development, utilization and their basic functions and design principles. During sensing of object (patient) may occur artifacts caused by scanning object (body movement, implants, beam hardening). The paper describe the most frequently artifacts and compare the parameters of medical and industrial CT machines.
Keywords: Computed tomography, measurement, artifacts, metrology
Published: October 31, 2013 Show citation
References
- ®ivčák, J., Hudák, R., Bednarčíková, L., Tóth, T., Trebuňová, M.: Biomechanizmy, implantáty na mieru, ISBN: 978-80-553-1396-2, s. 159, 2012
- Shampo, M. A., Kyle, R. A. Godfrey Hounsfield-developer of computed tomographic scanning. Mayo Clinic Proceeding, 71(10), p. 990, 1996
Go to original source...
- Seynaeve, P. C., BROOS, J. I.: The history oftomography. Journal Belgede Radiologie. 78(5), p. 284-288, 1995
Go to original source...
- Kalender, W. A.: Computed Tomography Fundamentals, System Technology, Image Quality, Applications. Munich: Publicis MCD, 220 p. ISBN 3-89578-081-2, 2000
- Reiser, M. F. et al.: Multislice CT. 3rd Ed. Berlin: Springer, 2009, 611 p. ISBN 978-3-540-33124-7. s. 5-10, 2009
Go to original source...
- Fuchs, T., Kachelriess, M., Kalender, W. A.: Technical advances in multislicespiral CT. European Journal Of Radiology, 2000, 36 (2), s. 69-73, 2000
Go to original source...
- Flohr, T. et al.: First performance evaluation of a dualsource CT (DSCT) system. European Radiology, 16 (2), p. 256-268, 2006
Go to original source...
- Jhaveri, K., S. et al.: Effect of multislice CT technology on scanner productivity. American Journal of Roentgenology, 177(4),p. 769-772, 2001
Go to original source...
- Endo, M et al.: Effect of scattered radiation on imagenoise in conebeam CT. Medical Physics, 28 (4), p. 469-474, 2001
Go to original source...
- Gupta, R. et al.: Ultra highre solution flat-panel volume CT: fundamental principles, design architecture, and system characterization. European Radiology. 16(6), s.1191-1205, 2005
Go to original source...
- Barrett, J. F., Keat, N.: Artifacts in CT: Recognition and Avoidance. Radio Graphics, 24 (6), p.1679-1691, 2004
Go to original source...
- Barrett, J. F. et al.: Cardiac CT scanning. In MHRA Report 03076. [online]. London, England: Medicines and Healthcare Products Regulatory Agency, 2003. 36 p. [cit.2010.06.06] Dostupné na internete: http://www.cep.dh.gov.uk/. ISBN 1 84182 746 0, 2003
- Seeram, E.:Computed tomography: physical principles, clinical applications and quality control. 2nd ed. Philadelphia, Pa: Saunders, ISBN 9780721681733. p. 174-199, 2001
- Trebuňová, M, Dankovčík, R., Repovský A. a kol.: Artefakty pri zobrazovaní ultrazvukom, Folia Medica Cassoviensia, in press
- ®ivčák, J, Trebuňová, M, Repovský, A, Laputková, G.: Artefakty spôsobené pacientom pri zobrazovaní magnetickou rezonanciou. Lékař a technika - Clinician and technology, ISSN 0301-5491, 2(43), s. 17-22, 2013
- ®ivčák, J, Trebuňová, M, Repovský, A, Laputková, G.: Magnetic resonance image artifact due to the examination method and scanning sequences. Acta Mechanica Slovaca, ISSN 1335 - 2393, 17 (3), s.88-92, 2013
Go to original source...
- Hudák, R., ®ivčák, J., Magin R.L.: Applications of Metrotomography in Biomedical Engineering In: Biomedical Engineering - Technical Applications in Medicine. - Rijeka : InTech, 2012 P. 225-244. - ISBN 978-953-51-0733-0
Go to original source...
- Kruth, J.P., Bartscherb, M., Carmignatoc, S., Schmittd, R., De Chiffree, L., Weckenmannf, A.: Computed tomography for dimensional metrology, CIRP Annals - Manufacturing Technology, Volume 60, Issue 2, 2011, Pages 821-842
Go to original source...
- Weiß, D., Shi Q., Kuhn Ch.: Measuring the 3D resolution of a micro-focus X-ray CT setup, http://www.ndt.net/article/ctc2012/papers/365.pdf
- Fedorko, G., Molnár, V., Marasová, D., Grinčová, A., Dovica, M., ®ivčák, J., Tóth, T., Husáková, N.: Failure analysis of belt conveyor damage caused by the falling material. Part 2: Application of computer metrotomography, In: Engineering failure analysis. Vol. 34 (2013), p. 431-442. - ISSN 1350-6307
Go to original source...
- Fedorko, G., Molnár, V., Marasová, D., Grinčová, A., Dovica, M., ®ivčák, J., Tóth, T., Husáková, N.: Failure analysis of belt conveyor damage caused by the falling material. Part 1: Experimental measurements and regression models, In: Engineering failure analysis. Vol. 36 (2014), p. 30-38. - ISSN 1350-6307
Go to original source...
- http://www.healthcare.siemens.com/
- www.gehealthcare.com/
This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.