Acta Mechanica Slovaca 2013, 17(3):88-92 | DOI: 10.21496/ams.2013.037
Magnetic Resonance Image Artifact Due to the Examination Method and Scanning Sequences
- 1 Department of Biomedical Engineering and Measurement DBEaM, Faculty of Mechanical Engineeering, Institute of Technical Sciences, TUKE, Letná 9, 042 00 Košice, Slovak Republic
- 2 Department of Medical and Clinical Biophysics, Pavol Jozef Šafárik University, Faculty of Medicine, Trieda SNP 1, 040 11 Košice, Slovak Republic
- 3 Department of Radiology, A. Leňa Hospital, Nemocničná 7, 066 01 Humenné, Slovak Republic
Magnetic resonance (MR) belongs to the most important diagnostic and imaging methods. It is derived from classic nuclear magnetic resonance that is the method based upon the difference between the magnetic properties of the diverse nuclei. However, this method, as well as the other non-invasive imaging methods, is burdened by the presence of the numerous artifacts. In addition to the artifacts due to the patient, the artifacts due to the method and the scanning sequences exist. In this review the main types of MR artifacts due to the examination method and the scanning sequences are presented. The characteristic properties and the physical and the technical preconditions of given artifacts are given.
Keywords: Artifacts, magnetic resonance, sequences
Published: October 31, 2013 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- Smith, A.S., Weinstein, M.A., Hurst, G.C., DeRemer, D.R., Cole, R.A., Duchesneau, P.M. (1990). Intracranial chemical shift artifacts on MR images of the brain: observations and relation to sampling bandwidth. Am J Roentgenol, 154, 6, 1275-1283.
Go to original source...
- Heiland, S. (2009). Detect and avoid artifacts. Radiologie up2date, 9, 4, 303-318.
Go to original source...
- Savci, G., Yazici, Z., Sahin, N., Akgöz, S., Tuncel, E. (2006). Value of chemical shift subtraction MRI in characterization of adrenal masses. Am J Roentgenol, 186, 1, 130-135.
Go to original source...
- Venkataraman, S., Braga, L., Semelka, R. (2002). Imaging the fatty liver. Magn Reson Imaging C, 10, 1, 93-103.
Go to original source...
- Czervionke, L.F., Czervionke, J.M., Daniels, D.L., Haughton, V.M. (1988). Characteristic features of MR truncation artifacts. Am J Roentgenol, 151, 9, 815-824.
Go to original source...
- Runge, V.M., Nitz, W.R., Schmeets, S.H. (2009). The Physics of Clinical MRI Taught Through Images. Thieme, New York.
Go to original source...
- Papadakis, N.G., Martine, K.M., Pickard, J.D., Hall, L.D., Carpenter, T. A., Huang, C.L. (2000). Gradient preempasis calibration in diffusion-weighted echo-planar imaging. Magn Reson Med, 44, 4, 616-624.
Go to original source...
This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.