Acta Mechanica Slovaca 2011, 15(1):64-69 | DOI: 10.21496/ams.2011.009

Actuators Placement for Active Damping of Vibration on Two Dimensional Clamped Plate

Peter Šolek, Martin Horínek

This article deals with the investigation of optimal actuator placement for two dimensional systems. In this article the two dimensional system is represented by a clamped plate. The intention of optimal actuator placement is to place actuators in minimal number of actuators to ensure controllability of the system. In this article is compared placement of force actuators and piezoelectric actuators. The approach proposed in this article is based on the evaluation of the H2 and H∞ norms. The optimal actuator placement satisfies the condition of controllability.

Keywords: Actuator Placement, Controllability, Norms, Two-Dimensional Flexible System

Published: March 31, 2011  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Šolek, P., & Horínek, M. (2011). Actuators Placement for Active Damping of Vibration on Two Dimensional Clamped Plate. Acta Mechanica Slovaca15(1), 64-69. doi: 10.21496/ams.2011.009
Download citation

References

  1. Gawronski W. K.: Advanced Structural Dynamics and Active Control of structures. Springer Verlag, New York, 2004 Go to original source...
  2. Liu, Wei, Hou, Zhokun, Demetrion, Michael A.: A computationa scheme for the optimal sensor/actuator placement of flexible structures using spatial H2 measures. Mechanical Systems and Signal processing. Volume 20,4, 2006, pp. 881-895 Go to original source...
  3. Hiramot K., Doki H., Obinata G: Optimal sensor/actuator placement for active vibration control. Journal of Sound and Vibrations. Volume 229,5,2000, pp. 1057-1075 Go to original source...
  4. DeLorenzo M.L.: Sensor and actuator selsction for large space structure control. Journal of Guidance, Control and Dynamics. Vol.13, 1990, pp. 249-257 Go to original source...
  5. Kim Y., Junkins J. L.: Measure of controllability for actuator placement. Journal of Guidance,Control and Dynamics. Vol. 14, 1991, pp. 895-902 Go to original source...
  6. Pulthasthan, Suwit, Pota, Hemanshu R.: Oprimal actuator-sensor placement for acoustic cavity. Poceedings of the IEEE Conference on Decision and Control, CDC, 2006, pp. 1684-1689 Go to original source...

This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.