PT Journal AU Cep, R Malotova, S Vrba, V TI Comparison of the Measuring Devices during the Evaluating of Circularity Deviation SO Acta Mechanica Slovaca PY 2017 BP 12 EP 16 VL 21 IS 3 DI 10.21496/ams.2017.021 DE metrology; circularity deviation; 3D device; measurement AB The contribution deals with the comparison of devices for measuring and evaluation of circularity of deviation. The circularity of deviation was measure on the specific component using in practice. The deviation was measured with using standard circular gauge Formtester MMQ 44 CNC and 3D measuring device SCAN Max. The results were statistical evaluated in tables. Part of the results is the technical and economic evaluation too. ER