PT Journal AU Simsik, D Galajdova, A Dolna, Z TI Variability of Gait Parameters in Different Daily Situations SO Acta Mechanica Slovaca PY 2010 BP 26 EP 35 VL 14 IS 1 DI 10.2478/v10147-011-0004-1 DE Human motion analysis; gait parameters; gait pattern; kinematics; SMART system AB Gait parameters of ten subjects were recorded in Human Motion Analysis Laboratory at Technical University of Kosice to provide data for gait pattern study. Subjects were walking by their self-selected walking speed and accelerated speed of walking in 3 different situations differing with type of cloths. System SMART was used to capture 3D coordinates of subjects' movement (6 infrared cameras, 50Hz) for each specific situation and different speed. The motion data available immediately after 3D gait data reconstruction in SMART Tracker software were time dependent position, velocity and acceleration of 25 markers. They provided input for further calculation and kinematic data analysis of human gait. The data analysis conducted in program SMART analyzer provides an overview about gait parameters variability in frame of investigated group of pendants. ER