Acta Mechanica Slovaca 2016, 20(2):42-46 | DOI: 10.21496/ams.2016.013
Comparison of the Performances of Absorption Refrigeration Cycles with Weak and Strong Ammonia-Water Solution
- 1 INA d.d., Avenija Većeslava Holjevca 10, 10 000 Zagreb, Croatia
- 2 University of Zagreb, Faculty of Metallurgy; Aleja narodnih heroja 3, 44 103 Sisak, Croatia
The absorption refrigeration system differs fundamentally from vapour compression system only in the method of compressing the refrigerant. So-called thermal-compressor, which consists of an absorber, generator and pump, replace the compressor of a vapour compression system. For heating process, instead electric energy, thermal energy in the form of saturated steam, hot water, natural gas or the waste heat sources are being used. In this article, on the example of single-effect absorption system using ammonia-water solution with ammonia as the refrigerant and water as the absorbent, research has been devoted to investigate theoretically the performance of two different operating modes of absorption refrigeration process with weak and strong ammonia-water solution in the generator.
Keywords: absorption, refrigeration, ammonia-water, strong, weak, solution, COP
Published: October 31, 2016 Show citation
References
- Ziegler, F (1999). Recent developments and future prospects of sorption heat pump system. International Journal of Thermal Science, 38, pp.191-208.
Go to original source...
- Srikhirin, P, Aphornratana, S, Chungpaibulpatana, S (2001). A review of absorption refrigeration technologies, Renewable and Sustainable Energy Reviews, 5, pp. 343-372.
Go to original source...
- Mohideen, S.T, Renganarayanan, S (2006). Heat and mass transfer studies on 134 A-DMAC based falling film absorbers for absorption refrigeration system, Proceedings of the 4th WSEAS Int. Conf. on Heat Transfer, Thermal Engineering and Environment, Elounda, Greece, pp. 342-350.
- Poberžnik, S, Goricanec, D, Krope, J (2007). Traditional vs. alternative energy house heating source, Proceedings of the 2ndIASME / WSEAS International Conference on Energy & Environment (EE'07), Portoroz, Slovenia, pp. 15-17.
- Feng X, Goswami D.Y (1999). Thermodynamic Properties of ammonia-water mixtures for Power-cycle application, Energy, 24, pp. 525-536.
Go to original source...
- Sun, D (1998). Comparison of the performances of NH3-H2O, NH3-LiNO3 and NH3-NaSCN absorption refrigeration systems, Energy Conversion and Management, 39, pp. 357-368.
Go to original source...
- Bošnjaković, F. (1986). Nauka o toplini III, Tehnička knjiga Zagreb
- Herold, K.E, Radermacher, R (1995). Absorption chillers and Heat Pumps, CRC Press, Inc., Boca Raton
This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.